FixVault

Enable Conditions

ENABLE CONDITIONS

Condition Minimum Maximum
Vehicle speed - 3 mph (5 km/h)
Shift lever position D, S, L, R(1)
D, S, R(2)
No active DTCs set (prevents monitor from running) P0335, P0336, P0501, P0502, P0705, P0706, P0716, P0717, P0721, P0722, P0746, P0777, P0962, P0963, P0966, P0967, P0970, P0971, P16C0, P16D8, P1898, P1899, P2122, P2123
Other The pulley ratio is less than 3.0
The engine speed is greater than the engine speed in graph 1
(1) Six-position transmission
(2) Five-position transmission