FixVault

Enable Conditions

ENABLE CONDITIONS

Condition Minimum Maximum
Drive pulley speed 600 rpm -
Vehicle speed 9 mph (14 km/h) -
Throttle position 5.25° -
Shift lever position D, S, L, R(1)
D, S, R(2)
No active DTCs set (prevents monitor from running) P0335, P0336, P0501, P0502, P0705, P0716, P0717, P0721, P0722, P0746, P0777, P0796, P0962, P0963, P0966, P0967, P0970, P0971, P16C0, P1898, P1899, P2122, P2123
(1) Six-position transmission
(2) Five-position transmission