IMA Motor Rotor Position Sensor Removal/Installation
- Remove the IMA motor housing (see DRAIN COVER REMOVAL/INSTALLATION ).
- Remove the bolts (A, B) and the IMA motor rotor position sensor (C).
- Install the parts in the reverse order of removal.NOTE: Tighten the bolts (A) first, then tighten the bolts (B).
- Do the motor rotor position calibration procedure (see IMA MOTOR ROTOR POSITION CALIBRATION ).