FixVault

EGR Valve Replacement

  1. Disconnect the EGR valve 5P connector (A).
    Fig 1: Locating EGR Valve 5P Connector And EGR Valve With Torque Specifications
    G06950129Courtesy of AMERICAN HONDA MOTOR CO., INC.
  2. Remove the EGR valve (B).
  3. Install the parts in the reverse order of removal with a new gasket (C).