FixVault

Connecting Rod Bolt Inspection: Inspection

Inspection

1. Connecting Rod Bolt - Inspection 

GHH124069Courtesy of HONDA, U.S.A., INC.
1. Measure the diameter of each connecting rod bolt at point A and point B.

2. Calculate the difference in diameter between point A and point B.

Point A - Point B = Difference in Diameter
Difference in Diameter
Specification: 0-0.05 mm (0-0.0020 in)

3. If the difference in diameter is out of specification, replace the connecting rod bolt.