Thermostat Test
Replace the thermostat if it is stuck in the open position at room temperature.
To test a closed thermostat:
- Suspend the thermostat (A) in a container of water. Do not let the thermometer (B) touch the bottom of the hot container.
- Heat the water, and check the temperature with a thermometer. Check the temperature when the thermostat first opens, then check the temperature again when the thermostat is fully open.
- Measure the lift height of the thermostat when it is fully open. If the thermostat is not within the specification, replace it.
Standard Thermostat
Lift Height: Above 8.0 mm (0.31 in.)
Starts Opening: 169-176°F (76-80°C)
Fully Open: 194°F (90°C)