FixVault

Mode $06 Information By Test: Misfire

DTC P0301: Monitor ID $A2: Test ID $0B

OBD Monitor ID $A2 Test ID $0B Unit and Scaling ID $24
DTC P0301
Test Description The average number of misfires detected during the last ten driving cycles for #1 cylinder.
(current misfire counts) x 0.1 + (previous misfire counts average) x 0.9
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 1 (time)
The lowest limit value: Not applicable
The highest limit value: Not applicable
DTC P0301: Monitor ID $A2: Test ID $0C

OBD Monitor ID $A2 Test ID $0C Unit and Scaling ID $24
DTC P0301
Test Description Total misfire counters in #1 cylinder on the present drive cycle. Previous drive cycle misfire counters are indicated from ignition switch is turned to ON (II) until engine start.
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 1 (time)
The lowest limit value: Not applicable
The highest limit value: Not applicable
DTC P0302: Monitor ID $A3: Test ID $0B

OBD Monitor ID $A3 Test ID $0B Unit and Scaling ID $24
DTC P0302
Test Description The average number of misfires detected during the last ten driving cycles for #2 cylinder.
(current misfire counts) x 0.1 + (previous misfire counts average) x 0.9
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 1 (time)
The lowest limit value: Not applicable
The highest limit value: Not applicable
DTC P0302: Monitor ID $A3: Test ID $0C

OBD Monitor ID $A3 Test ID $0C Unit and Scaling ID $24
DTC P0302
Test Description Total misfire counters in #2 cylinder on the present drive cycle. Previous drive cycle misfire counters are indicated from ignition switch is turned to ON (II) until engine start.
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 1 (time)
The lowest limit value: Not applicable
The highest limit value: Not applicable
DTC P0303: Monitor ID $A4: Test ID $0B

OBD Monitor ID $A4 Test ID $0B Unit and Scaling ID $24
DTC P0303
Test Description The average number of misfires detected during the last ten driving cycles for #3 cylinder.
(current misfire counts) x 0.1 + (previous misfire counts average) x 0.9
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 1 (time)
The lowest limit value: Not applicable
The highest limit value: Not applicable
DTC P0303: Monitor ID $A4: Test ID $0C

OBD Monitor ID $A4 Test ID $0C Unit and Scaling ID $24
DTC P0303
Test Description Total misfire counters in #3 cylinder on the present drive cycle. Previous drive cycle misfire counters are indicated from ignition switch is turned to ON (II) until engine start.
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 1 (time)
The lowest limit value: Not applicable
The highest limit value: Not applicable
DTC P0304: Monitor ID $A5: Test ID $0B

OBD Monitor ID $A5 Test ID $0B Unit and Scaling ID $24
DTC P0304
Test Description The average number of misfires detected during the last ten driving cycles for #4 cylinder.
(current misfire counts) x 0.1 + (previous misfire counts average) x 0.9
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 1 (time)
The lowest limit value: Not applicable
The highest limit value: Not applicable
DTC P0304: Monitor ID $A5: Test ID $0C

OBD Monitor ID $A5 Test ID $0C Unit and Scaling ID $24
DTC P0304
Test Description Total misfire counters in #4 cylinder on the present drive cycle. Previous drive cycle misfire counters are indicated from ignition switch is turned to ON (II) until engine start.
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 1 (time)
The lowest limit value: Not applicable
The highest limit value: Not applicable
DTC P0305: Monitor ID $A62: Test ID $0B

OBD Monitor ID $A6 Test ID $0B Unit and Scaling ID $24
DTC P0305
Test Description The average number of misfires detected during the last ten driving cycles for #5 cylinder.
(current misfire counts) x 0.1 + (previous misfire counts average) x 0.9
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 1 (time)
The lowest limit value: Not applicable
The highest limit value: Not applicable
DTC P0305: Monitor ID $A6: Test ID $0C

OBD Monitor ID $A6 Test ID $0C Unit and Scaling ID $24
DTC P0305
Test Description Total misfire counters in #5 cylinder on the present drive cycle. Previous drive cycle misfire counters are indicated from ignition switch is turned to ON (II) until engine start.
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value lift: Output value (Decimal) x 1 (time)
The lowest limit value lift: Not applicable
The highest limit value lift: Not applicable
DTC P0306: Monitor ID $A7: Test ID $0B

OBD Monitor ID $A7 Test ID $0B Unit and Scaling ID $24
DTC P0306
Test Description The average number of misfires detected during the last ten driving cycles for #6 cylinder.
(current misfire counts) x 0.1 + (previous misfire counts average) x 0.9
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 1 (time)
The lowest limit value: Not applicable
The highest limit value: Not applicable
DTC P0306: Monitor ID $A7: Test ID $0C

OBD Monitor ID $A7 Test ID $0C Unit and Scaling ID $24
DTC P0306
Test Description Total misfire counters in #6 cylinder on the present drive cycle. Previous drive cycle misfire counters are indicated from ignition switch is turned to ON (II) until engine start.
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value lift: Output value (Decimal) x 1 (time)
The lowest limit value lift: Not applicable
The highest limit value lift: Not applicable