Enable Conditions

Condition Minimum Maximum
IMA motor speed 500 rpm 1,500 rpm
IMA motor driving torque 10 N.m (1 kgf.m, 7.2 lbf.ft) -
No active DTCs set (prevents monitor from running) P0602 (91), P0602 (92), P062F (60), P06B1, P0A1B, P0A3C, P0A3F, P0A5E, P0A5F, P0A61, P0A62, P0A64, P0A65, P0A78, P0A7E, P0AC0, P0AC1, P0AC2, P0AE1, P0B0F, P0B10, P0B11, P0BE6, P0BEA, P0BEE, P0BFD, P1437, P1570, P1575, P1586, P15A5, P1634, U0038, U0311, U0312, U1204