FixVault

Enable Conditions

Condition Minimum Maximum
Elapsed time after application of power to A/F sensor heater starts 60 seconds -
Engine coolant temperature 156 °F (69 °C) -
Intake air temperature -13 °F (-25 °C) -
Engine speed 1,500 rpm 3,000 rpm
MAP value 1,500 rpm 67 kPa (19.7 inHg, 500 mmHg) 94 kPa (27.6 inHg, 700 mmHg)
3,000 rpm 60 kPa (17.8 inHg, 450 mmHg)
Vehicle speed 33 mph (52 km/h) -
Fuel trim 0.75 1.47
Fuel feedback Closed loop at stoichiometric
Monitoring priority P0400, P219A
No active DTCs set (prevents monitor from running) P0101, P0102, P0103, P0107, P0108, P0112, P0113, P0117, P0118, P0134, P0135, P0171, P0172, P0201, P0202, P0203, P0204, P0300, P0301, P0302, P0303, P0304, P0335, P0339, P0351, P0352, P0400, P0401, P0404, P0443, P0496, P0497, P0522, P0523, P1109, P1157, P1172, P145C, P2195, P2227, P2228, P2229, P2238, P2252, P2413, P2648, P2649, P2A00
Other Without excessive load change