FixVault

DTC U1282: Door Multiplex Control Unit Lost Communication With MICU

NOTE: If you are troubleshooting multiple DTCs, be sure to follow the instructions in B-CAN System Diagnosis Test Mode A (see TROUBLESHOOTING - B-CAN SYSTEM DIAGNOSIS TEST MODE A ).
  1. Clear the DTCs with the HDS.
  2. Turn the ignition switch to LOCK (0) and then back to ON (II).
  3. Wait for at least 6 seconds.
  4. Check for DTCs with the HDS.

    Is DTC U1282 indicated? 

    YES  -Go to the MICU input test, and do all power, ground and communication input tests (see CONTROL UNIT INPUT TEST ). If the tests prove OK, replace the under-dash fuse/relay box (see REMOVAL AND INSTALLATION ).

    NO  -Intermittent failure, the system is OK at this time. Check for loose or poor connections at under-dash fuse/relay box connector P (10P) and the related units.