FixVault

DTC P0714 (6-Speed A/T)

DTC P0714  : ATF Temperature Sensor (Intermittent Failure)

NOTE: 

DTC Description Confirmed DTC Pending DTC Freeze Frame
P0714 ATF Temperature Sensor (Intermittent Failure)      

DTC (A/T)

  1. Current ATF temperature check

    - 1. Turn the vehicle to the ON mode.

    - 2. Check the parameter (s) below with the HDS.

    A/T System 

    Signal Current conditions
    Values Unit
    ATF Temperature    

    PGM-FI System 

    Signal Current conditions
    Values Unit
    ECT SENSOR 2    

    Are the ATF Temperature and ECT SENSOR 2 equal to the ambient air temperature?

    YES 

    Record the values of the ATF Temperature and ECT SENSOR 2 with the HDS, then go to step 3.

    NO 

    Go to step 2.

  2. ATF temperature difference check

    - 1. Turn the vehicle to the OFF (LOCK) mode, and wait for at least 30 minutes.

    - 2. Turn the vehicle to the ON mode.

    - 3. Compare the current ATF Temperature to the ATF Temperature recorded in step 1-2.

    Signal Current conditions
    Values Unit
    ATF Temperature    

    Does the ATF Temperature change?

    YES 

    Leave the engine off for at least 6 hours, then go to step 3.

    NO 

    Replace the ATF temperature sensor .

  3. ATF temperature sensor check

    - 1. Compare the values of the ATF Temperature and ECT SENSOR 2 with the HDS.

    A/T System 

    Signal Current conditions
    Values Unit
    ATF Temperature    

    PGM-FI System 

    Signal Current conditions
    Values Unit
    ECT SENSOR 2    

    Is the value of the ATF Temperature higher than the value of ECT SENSOR 2 by 58 °F (32 °C), or is the value of the ATF Temperature lower than the value of ECT SENSOR 2 by 43 °F (24 °C)?

    YES 

    Replace the ATF temperature sensor .

    NO 