Engine Control System - Advanced Diagnostics (P1684 - U129E)
›
Advanced Diagnostics
›
DTC P2413
›
Enable Conditions
Enable Conditions
Condition
Minimum
Maximum
Engine speed [ENGINE SPEED]
-
4, 800 rpm
Commanded EGR valve lift
1 mm (0.04 in)
-
12 volt battery voltage [BATTERY]
10.5 V
-
[ ]: HDS Parameter