FixVault

Power Window Master Switch Connector for Inputs and Outputs

Power Window Master Switch 37P Connector (female terminals) 

GHH388944Courtesy of HONDA, U.S.A., INC.
Terminal number Terminal name Description Signal
1 P/W DR MTR DOWN Drives driver's power window motor With driver's power window motor DOWN operation: about battery voltage
If none of the above conditions are met: less than 0.2 V
2 P/W DR MTR UP Drives driver's power window motor With driver's power window motor UP operation: about battery voltage
If none of the above conditions are met: less than 0.2 V
3 GND Ground for power window master switch Less than 0.2 V at all times
4 +B P/W DR +B power source About battery voltage at all times
5 Not used --- ---
6 Not used --- ---
7 DR KEY CYL LOCK Detects DR KEY CYL LOCK signal With driver's door key cylinder switch UNLOCK: about battery voltage
With driver's door key cylinder switch LOCK: less than 0.2 V
8 DR KEY CYL UNLOCK Detects DR KEY CYL UNLOCK signal With driver's door key cylinder switch LOCK: about battery voltage
With driver's door key cylinder switch UNLOCK: less than 0.2 V
9 TRUNK OPEN SW(INTR) Detects TRUNK OPEN SW(INTR) signal With trunk lid opener switch ON: less than 0.2 V
With trunk lid opener switch OFF: about battery voltage
10 MIRROR R COM Detects MIRROR R COM signal With vehicle in ON mode and right power mirror DOWN or LEFT function: about battery voltage
11 MIRROR R LR Detects MIRROR R LR signal With vehicle in ON mode and right power mirror DOWN or RIGHT function: about battery voltage
12 MIRROR UD Detects MIRROR UD signal With vehicle in ON mode and power mirror UP or LEFT function: about battery voltage
13 P/W RR L SW RLY UP Drives left rear power window motor With left rear power window moving to UP using power window master switch: about battery voltage
If none of above conditions are met: less than 0.2 V
14 P/W RR L SW RLY DOWN Drives left rear power window motor With left rear power window moving to DOWN using power window master switch: about battery voltage
If none of above conditions are met: less than 0.2 V
15 * H/MIRROR DR Drives left power mirror defogger With mirror defogger ON: about battery voltage
16 Not used --- ---

*: With mirror defogger

Terminal number Terminal name Description Signal
17 Not used --- ---
18 IG2 OPTION IG2 power source With vehicle in ON mode: about battery voltage
19 Not used --- ---
20 DR SILCON UNLOCK Detects DR SILCON UNLOCK signal With driver's door lock knob switch LOCK: about battery voltage
With driver's door lock knob switch UNLOCK: less than 0.2 V
21 DR SILCON LOCK Detects DR SILCON LOCK signal With driver's door lock knob switch UNLOCK: about battery voltage
With driver's door lock knob switch LOCK: less than 0.2 V
22 Not used --- ---
23 Not used --- ---
24 Not used --- ---
25 P/W RR R SW RLY DOWN Drives right rear power window motor With right rear power window moving to DOWN using power window master switch: about battery voltage
If none of above conditions are met: less than 0.2 V
26 P/W RR R SW RLY UP Drives right rear power window motor With right rear power window moving to UP using power window master switch: about battery voltage
If none of above conditions are met: less than 0.2 V
27 Not used --- ---
28 Not used --- ---
29 GND Ground for power window master switch Less than 0.2 V at all times
30 P/W SW ILLUMI Outputs P/W SW ILLUMI signal With combination light switch PARKING: about battery voltage
With combination light switch OFF: less than 0.2 V
31 B-CAN_L Communication line ---
32 B-CAN_H Communication line ---
33 P/W DR MTR PLSA Detects P/W DR MTR PLSA signal ---
34 P/W DR MTR VCC Drives driver's power window motor hall IC (pulser) unit With door multiplex control unit is wake-up mode and driver's power window motor operation: about battery voltage
If none of above conditions are met: less than 0.2 V
35 P/W DR MTR PLSB Detects P/W DR MTR PLSB signal ---
36 LIN(P/W) Communication line ---
37 +B BACK UP +B power source About battery voltage at all times

*: With mirror defogger