FixVault

VSA Off Switch Test: Test

How to use this service information .

  1. VSA OFF Switch - Test

    Preconditions 

    Figure 1 (4P connector type) 

    GHH543455Courtesy of HONDA, U.S.A., INC.

    Figure 2 (4P connector type) 

    GHH543456Courtesy of HONDA, U.S.A., INC.

    Figure 3 (12P connector type) 

    GHH543457Courtesy of HONDA, U.S.A., INC.

    Figure 4 (12P connector type) 

    GHH543458Courtesy of HONDA, U.S.A., INC.

    Procedure/Specifications 

    • Check the switch according to the table. (Figure 1, 2, 3, and 4)
      NOTE:
      • When an LED is located between terminals, check if the LED lights by connecting power and ground to the LED.
      • Note this important operating characteristic; diode bias causes a diode to fully conduct electricity in one direction (forward), while not at all in the opposite direction (reverse).

    Result 

    • If the result is not as specified, replace the VSA OFF switch.