DTC P16F6: Inspection
ST_CUT_RLY2_CL- Shorted Wire Inspection
NOTICE:
Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.
Test Procedure
- Preparation
- Relay circuit board connector B (12P): disconnected
- PCM connector B (72P): disconnected
- Procedure
- Perform the inspection according to the following chart.
Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
- Perform the inspection according to the following chart.
| (Disconnected) Relay circuit board connector B (12P) female terminals | ||||
| IG Mode |
|
Normal Conditions | ||
| ST_CUT_RLY2_CL- shorted to power inspection | ON | Not shorted |
Results
- If abnormal, there is a problem in the circuit.
PCM Inspection
Test Procedure
- If the other inspection item(s) indicated a normal condition, then it is determined that the remaining PCM is the cause.
Results
- There is a problem with the PCM.