FixVault

DTC P055C: Inspection

Rocker Arm Oil Pressure Sensor Inspection 

NOTE:  Since there is no direct method to test the component itself, troubleshooting is performed on the related components.

Test Procedure 

         
      (Disconnected) Rocker arm oil pressure sensor connector (3P) female terminals  
    IG Mode
GHH577288Courtesy of HONDA, U.S.A., INC.

Normal Conditions
  Unit output voltage inspection  ON About 5.0 V 
  ON About 5.0 V 
     

Results 

VCC11, POILCS Circuit Inspection 

NOTICE:  

Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.

Test Procedure 

           
      (Disconnected) Rocker arm oil pressure sensor connector (3P) female terminals (Disconnected) PCM connector E (114P) female terminals  
    IG Mode
GHH577291Courtesy of HONDA, U.S.A., INC.

GHH577292Courtesy of HONDA, U.S.A., INC.

Normal Conditions
  VCC11 open wire inspection  OFF There is less than 1 Ω 
  Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
  POILCS shorted to ground inspection  OFF   There is more than 1 MΩ 

Results 

PCM Inspection 

Test Procedure 

Results