DTC P0462: Inspection
FUEL_GAUGE+ Shorted Wire Inspection
Test Procedure
- Preparation
- Fuel tank unit connector (4P): disconnected
- Gauge control module connector A (32P): disconnected
- Procedure
- Perform the inspection according to the following chart.
Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
- Perform the inspection according to the following chart.
| (Disconnected) Fuel tank unit connector (4P) female terminals | ||||
| IG Mode |
|
Normal Conditions | ||
| FUEL_GAUGE+ shorted to ground inspection | OFF | There is more than 1 MΩ |
Results
- If it is abnormal, there is a problem in the circuit.
Gauge Control Module Inspection
Test Procedure
- If the other inspection item(s) indicated a normal condition, then it is determined that the remaining gauge control module is the cause.
Results
- There is a problem with the gauge control module.