FixVault

DTC P0498: Inspection

EVAP Canister Vent Shut Valve Component Inspection 

Test Procedure 

         
      (Disconnected) EVAP canister vent shut valve connector (2P) male terminals  
    IG Mode
GHH577247Courtesy of HONDA, U.S.A., INC.
Normal Conditions
  Valve internal circuit inspection  OFF About 25 - 30 Ω (at room temperature) 
   

Results 

IGPS(EONV) [IGPS(LAF)] Open Wire Inspection 

Test Procedure 

           
      (Disconnected) EVAP canister vent shut valve connector (2P) female terminals (Disconnected) Power distribution module connector D (4P) female terminals  
    IG Mode
GHH577249Courtesy of HONDA, U.S.A., INC.

GHH577250Courtesy of HONDA, U.S.A., INC.

Normal Conditions
  IGPS(EONV) [IGPS(LAF)] open wire inspection  OFF There is less than 1 Ω 

Results 

VSSV Circuit Inspection 

NOTICE:  

Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.

Test Procedure 

           
      (Disconnected) EVAP canister vent shut valve connector (2P) female terminals (Disconnected) PCM connector B (72P) female terminals  
    IG Mode
GHH577252Courtesy of HONDA, U.S.A., INC.

GHH577253Courtesy of HONDA, U.S.A., INC.

Normal Conditions
  VSSV open wire inspection  OFF There is less than 1 Ω 
  Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
  VSSV shorted to ground inspection  OFF   There is more than 1 MΩ 

Results 

PCM Inspection 

Test Procedure 

Results