FixVault

Enable Conditions

Condition Minimum Maximum
Elapsed time that secondary HO2S activity is not monitored after starting the engine 15 seconds -
Engine coolant temperature [ECT Sensor 1] 155.9°F (68.8°C) -
Intake air temperature [IAT Sensor (1)] -13°F (-25°C) -
Estimated TWC temperature 1, 040°F (560°C) -
Vehicle speed [Vehicle Speed] 30 mph (48 km/h) -
Fuel trim 0.69 1.47
Fuel feedback Closed loop at stoichiometric
Monitoring priority P0133
Other Has record of deceleration at least once
Cruise load or more

[ ]: HDS Parameter