FixVault

Enable Conditions

Common Conditions 

Condition Minimum Maximum
Barometric pressure [Baro Sensor] 76 kPa (569 mmHg, 22.5 inHg) -
12 volt battery voltage [Battery] 10.5 V -
Other No refueling during the driving cycle

[ ]: HDS Parameter

Conditions before soak 

Condition  
Other Driven for certain minutes

Conditions during soak 

Condition Minimum Maximum
Soak duration 5 hours -

Malfunction Threshold 

The reference pressure is -5.1 kPa (-38.1 mmHg, -1.5 inHg) or less.