Possible Cause
NOTE: The causes shown may not be a complete list of all potential problems, and it is possible that there may be other causes.
- Electric VTC motor EVTP line open
- Electric VTC motor EVTM line open
- Electric VTC motor EVTC_GND line open
- Electric VTC motor EVTP line short
- Electric VTC motor EVTM line short
- Electric VTC motor EVTC_GND line short
- Electric VTC motor VB1(EVTC) line short to ground
- Electric VTC relay EVTC_RLY_CL- line open
- Electric VTC relay EVTC_RLY_CL- line short to power
- Electric VTC relay stuck off