FixVault

Malfunction Threshold

The transmission fluid pressure sensor E value is in abnormal range against the brake B2 commanded pressure shown in the following table.

Brake B2 commanded pressure  Examples of representative transmission control mode  Transmission fluid pressure sensor E value 
11 kPa (0.11 kgf/cm 2, 1.5 psi) or less
  • In Parking
  • Steady 4th gear ratio
  • Steady 5th gear ratio
  • Steady 6th gear ratio
More than 300 kPa (3.06 kgf/cm 2, 43.5 psi)
More than 11 kPa (0.11 kgf/cm 2, 1.5 psi) and line pressure commanded pressure or more
  • Steady 1st gear ratio
  • Steady 2nd gear ratio
  • Steady 3rd gear ratio
Value or more obtained by adding 300 kPa (3.06 kgf/cm 2, 43.5 psi) to the line pressure commanded pressure or value or less obtained by subtracting 300 kPa (3.06 kgf/cm 2, 43.5 psi) from the line pressure commanded pressure when clutch pressure control solenoid valve A, regulator valve, and fluid passage are normal
More than 11 kPa (0.11 kgf/cm 2, 1.5 psi) and less than line pressure commanded pressure
  • Upshift from 3rd to 4th gear
  • Downshift from 7th to 6th gear
More than value obtained by adding 400 kPa (4.08 kgf/cm 2, 58.0 psi) to brake B2 commanded pressure and more than 300 kPa (3.06 kgf/cm 2, 43.5 psi)