FixVault

Enable Conditions

Condition Minimum Maximum
Engine speed [Engine Speed] 500 rpm -
12 volt battery voltage [Battery Voltage] 10 V -
Control command to shift solenoid valve D OFF
Other Transmission fluid pressure sensor C value is more than 300 kPa (3.06 kgf/cm 2, 43.5 psi) or transmission fluid pressure sensor E value is more than 300 kPa (3.06 kgf/cm 2, 43.5 psi)

[ ]: HDS Parameter