FixVault

DTC B12D0 (Keyless Access Power Control Unit): Inspection

IG1-A_SIG, IG1_COIL+ Circuit Inspection 

Test Procedure 

           
      (Disconnected) Under-dash fuse/relay box connector D (16P) female terminals (Disconnected) Body control module connector C (66P) female terminals  
    IG Mode
GHH580280Courtesy of HONDA, U.S.A., INC.

GHH580281Courtesy of HONDA, U.S.A., INC.

Normal Conditions
  IG1_COIL+ open wire inspection  OFF There is less than 1 Ohms 
  IG1-A_SIG open wire inspection  OFF There is less than 1 Ohms 
  Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
  IG1-A_SIG shorted to ground inspection  OFF   There is more than 1 MOhms 

Results