FixVault

DTC B1648 (Keyless Access Control Unit): Inspection

EXT_FR_AS+, EXT_FR_AS- Open Wire Inspection 

Test Procedure 

           
      (Disconnected) Right-front LF antenna/initiator connector (2P) female terminals (Disconnected) Body control module connector C (66P) female terminals  
    IG Mode
GHH580154Courtesy of HONDA, U.S.A., INC.

GHH580155Courtesy of HONDA, U.S.A., INC.

Normal Conditions
  EXT_FR_AS+ open wire inspection  OFF There is less than 1 Ohms 
  EXT_FR_AS- open wire inspection  OFF There is less than 1 Ohms 

Results 

EXT_FR_AS+, EXT_FR_AS- Shorted Wire Inspection 

Test Procedure 

         
      (Disconnected) Body control module connector C (66P) female terminals  
    IG Mode
GHH580158Courtesy of HONDA, U.S.A., INC.

Normal Conditions
  EXT_FR_AS+, EXT_FR_AS- shorted wire to wire inspection  OFF There is more than 1 MOhms 

Results 

Body Control Module Inspection 

Preconditions 

NOTE:  This procedure can be done before any other inspections are completed because this test procedure includes all of the following inspection items. However, if this test fails, it will be necessary to continue with each inspection item individually to determine which item failed.

Test Procedure 

*1: If the matter whether the vehicle mode ON or OFF (LOCK) because of the permanent power supply.

      (Disconnected) Right-front LF antenna/initiator connector (2P) female terminals  
    IG Mode
GHH580160Courtesy of HONDA, U.S.A., INC.

Normal Conditions
  Module internal circuit inspection  ON*1 Voltage 

*1: If the matter whether the vehicle mode ON or OFF (LOCK) because of the permanent power supply.

Results 

Right-Front LF Antenna/Initiator Inspection 

Test Procedure 

Results