FixVault

Installation Procedure

    Fig 1: Blower Motor Control Processor & HVAC Module Assembly
    GM826796Courtesy of GENERAL MOTORS CORP.
  1. Install the blower motor control processor (3) to the HVAC module assembly.
  2. NOTE: Refer to FASTENER NOTICE .
  3. Install the screws to the blower motor control processor (3).

    Tighten:  Tighten the screws to 1.6 N.m (14 lb in).

  4. Connect the electrical connector (4) to the blower motor control processor (3).
  5. Connect the electrical connector (2) to the blower motor (1).
  6. Install the I/P insulator panel. Refer to Insulator Replacement - Instrument Panel (I/P) .