Installation Procedure
- Install the recirculation actuator (1) to the HVAC module assembly (2).
- Install the screws to the recirculation actuator (1).
Tighten: Tighten the screws to 2 N.m (18 lb in).
- Connect the electrical connector to the recirculation actuator.
- Install the HVAC module assembly. Refer to HVAC Module Assembly Replacement .
- Reprogram the recirculation actuator. Refer to Re-Calibrating Actuators .
NOTE:
Refer to Fastener Notice
.