FixVault

Installation Procedure

    Fig 1: View Of Recirculation Actuator & Recirculation Housing
    GM826725Courtesy of GENERAL MOTORS CORP.
  1. Install the recirculation actuator (1) to the HVAC module assembly (2).
  2. NOTE: Refer to Fastener Notice .
  3. Install the screws to the recirculation actuator (1).

    Tighten:  Tighten the screws to 2 N.m (18 lb in).

  4. Connect the electrical connector to the recirculation actuator.
  5. Install the HVAC module assembly. Refer to HVAC Module Assembly Replacement .
  6. Reprogram the recirculation actuator. Refer to Re-Calibrating Actuators .