FixVault

Circuit/System Testing

  1. Ignition OFF, disconnect the harness connector of the ECM. Verify that there is less than 1.0 ohm between the ground circuits and the negative battery terminal.
    • If greater than the specified value, test the ground circuit for an open/high resistance.
  2. Ignition ON, test for 11-14 volts between the battery positive voltage and the ground circuits of the ECM.
    • If not within the specified range, test the battery positive voltage circuits for a short to ground or an open/high resistance.
  3. If all circuits test normal, test or replace the ECM.