FixVault

Fuel Pump Flow Control Module Replacement

Fig 1: Fuel Pump Flow Control Module
GM1971826Courtesy of GENERAL MOTORS CORP.
Callout Component Name
1 Fuel Pump Flow Control Module Bolt (Qty: 3)
NOTE: Refer to Fastener Notice .

Procedure: 
Disconnect the electrical connector.
Tip:  The bolts used are two headed and can be loosened from either side.

Tighten:  9 N.m (80 lb in)

2 Fuel Pump Flow Control Module
Procedure: 
If replacing the fuel pump flow control module, program the control module. Refer to Control Module References .