FixVault

Circuit/System Testing

  1. Ignition OFF, disconnect the harness connectors at the ECM.
  2. Ignition OFF, test for less than 5 ohms between the ground circuit terminal 73 X2 and ground:
    • If greater than the specified range, test the ground circuit for an open/high resistance.
  3. Verify that a test lamp illuminates between the B+ circuit terminal 20 X1 and ground:
    • If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
  4. Verify that a test lamp illuminates between the ignition circuit terminals listed below and ground:
    • Terminal 19 X1
    • Terminal 13 X2
    • If the test lamp does not illuminate, test the ignition circuit for a short to ground or an open/high resistance.
  5. If all circuits test normal, replace the EBCM.