FixVault

Removal Procedure

WARNING: Refer to Battery Disconnect Warning .
  1. Disconnect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection .
  2. Fig 1: View Of Generator Cable & Nut
    GM395686Courtesy of GENERAL MOTORS CORP.
  3. Remove the generator cable from the generator, perform the following:
    1. Reposition the boot to expose the stud.
    2. Remove the generator cable nut.
    3. Remove the generator cable from the stud.
  4. Fig 2: Identifying Cables At Junction Block
    GM662521Courtesy of GENERAL MOTORS CORP.
  5. Open the positive cable junction block.
  6. Remove the generator cable nut.
  7. Remove the generator cable (2) from the junction block.