Typical Scan Tool Data

AIR Pressure Sensor

Circuit Normal Range Short to Ground Open Short to Voltage
Operating Conditions:  Key ON, Engine OFF
5V Reference Voltage BARO 41 kPa 41 kPa 111 kPa
Pressure Sensor Signal BARO 42 kPa 41 kPa 150 kPa
Low Reference BARO BARO 145 kPa BARO