FixVault

Circuit/System Testing

  1. Ignition OFF, disconnect harness connector of the fuel pressure sensor.
  2. Ignition OFF, test for less than 1.0 ohm between the low reference circuit terminal 2 and ground.
    • If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the FPCM.
  3. Ignition ON, test for 4.8-5.2 volts between the 5-volt reference circuit terminal 3 and ground.
    • If less than the specified range, test the 5-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the FPCM.
    • If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the FPCM.
  4. If all circuits test normal, replace the fuel pressure sensor.