FixVault

Component Testing

  1. Ignition OFF, disconnect the Secondary Air Injection Pump Relay.
  2. Test for 50-75 Ω between terminals 85 and 86.
    • If the resistance is not within the specified range, replace the Secondary Air Injection Pump Relay.
  3. Test for infinite resistance between the following terminals:
    • 86 and 87
    • 86 and 30
    • 85 and 87
    • 87 and 30
    • If not the specified value, replace the Secondary Air Injection Pump Relay.
  4. Install a 20 A fused jumper wire between relay terminal 86 and B+. Install a jumper wire between relay terminal 85 and ground. Test for less than 2 Ω between terminals 87 and 30.
    • If greater than the specified range, replace the Secondary Air Injection Pump Relay.