Hazard Warning Switch
Ensure continuity exists between specified terminals of multifunction switch connector "B". See HAZARD SWITCH CONTINUITY TEST . Check connector terminal identification. SeeFig 1 .
HAZARD SWITCH CONTINUITY TEST
| Switch Position | Terminal Numbers | Continuity | |
|---|---|---|---|
| Hazard Switch Off | |||
| Left | 1 & 2; 5 & 11 | Yes | |
| Neutral | 5 & 11 | Yes | |
| Right | 1 & 3; 5 & 11 | Yes | |
| Hazard Switch On | |||
| Left, | 1, 2, 3 & 4; 11 & 12 | Yes | |
| Neutral | 1, 2, 3 & 4; 11 & 12 | Yes | |
| Right | 1, 2, 3 & 4; 11 & 12 | Yes | |