FixVault

Hazard Warning Switch

Ensure continuity exists between specified terminals of multifunction switch connector "B". See HAZARD SWITCH CONTINUITY TEST  . Check connector terminal identification. SeeFig 1 .

Fig 1: Multifunction Switch Connector Terminal ID
G92A00273Courtesy of HYUNDAI MOTOR CO.
HAZARD SWITCH CONTINUITY TEST

Switch Position Terminal Numbers Continuity
Hazard Switch Off
Left 1 & 2; 5 & 11 Yes
Neutral 5 & 11 Yes
Right 1 & 3; 5 & 11 Yes
Hazard Switch On
Left, 1, 2, 3 & 4; 11 & 12 Yes
Neutral 1, 2, 3 & 4; 11 & 12 Yes
Right 1, 2, 3 & 4; 11 & 12 Yes