  1. Starter relay is located in relay panel under left side of dash. Starter relay is at top left corner of relay panel. Remove relay. Check for continuity between terminals No. 1 and 3 of relay.
  2. If continuity exists, apply 12 volts to terminals No. 1 and 3 (No. 3 is relay ground terminal) to energize relay. Continuity should exist between terminals No. 2 and 4. If relay does not perform as described, replace relay.