FixVault

Power Mirror Motor

Access and disconnect power mirror motor connector. SeeFig 1 . Apply battery voltage between indicated motor terminals. See POWER MIRROR MOTOR TEST table. SeeFig 2 . Replace motor if it does not operate as specified.

POWER MIRROR MOTOR TEST

Battery + Lead (1) Battery - Lead (1) Mirror Operation
1 2 Up
2 1 Down
3 2 Left
2 3 Right
(1) Connect appropriate battery lead to indicated terminal.
Fig 1: Locating Power Mirror Motor Connector
G94E46684Courtesy of HYUNDAI MOTOR CO.
Fig 2: Identifying Power Mirror Motor Terminals
G94G46686Courtesy of HYUNDAI MOTOR CO.