FixVault

Service Standard

SERVICE SPECIFICATIONS

Items Engine Specifications Condition
Basic idle RPM SOHC 800 +/- 100 A/CON "ON" or "OFF (N-range)
DOHC 800 +/- 100 A/CON "ON" or "OFF (N-range)
Ignition timing (°) (at idle RPM) SOHC 9° +/- 5° A/CON "OFF" (N-range)
DOHC 9° +/- 5° A/CON "OFF" (N-range)