FixVault

Component Inspection

  1. Check HO2S heater
    1. Measure resistance between terminal 3 and 4 of sensor connector (To sensor side

      Specification: 80°C: 8.0~14.0Ω

      Fig 1: Measuring Resistance Between Terminals 3 And 4 Of Sensor Connector
      G03851689Courtesy of HYUNDAI MOTOR CO.
    2. Is measure resistance within Specification?

      YES 

      • Substitute with a known-good PCM and check for proper operation. If the problem is corrected, replace PCM and then go to "VERIFICATION OF VEHICLE REPAIR " procedure.

      NO 

      • Substitute with a known-good HO2S heater and check for proper operation. If the problem is corrected, replace HO2S heater and then go to "VERIFICATION OF VEHICLE REPAIR " procedure.