FixVault

DTC P0133: O2 Sensor Circuit Slow Response (Bank1/Sensor1): Specification

HO2S SPECIFICATION

HO2S Normal Parameter (at 1300 RPM after warming up)
Rich Lean
Signal Voltage 0.6~1.0V 0~0.4V
Hi-scan Data display Engine condition
When deceleration suddenly from 4000 RPM 200 mV or lower
When engine is suddenly raced 600~1000 mV