FixVault

Inspection Procedures

  1. CHECK DTC RELATING TO ECTS
    1. Connect a Hi-Scan (Pro) to the data link connector.
    2. Turn ignition to ON position and monitor other DTCs.

    Are any DTC relating to ECTS set? 

    No: Go to next

    Yes: Do all repairs associated with those codes before proceeding with this procedure.

  2. CHECK ENGINE COOLANT
    1. CHECK engine coolant level. 
    2. Measure the specific gravity of the coolant with a hydrometer.

    Yes: Go to next

    No: Replace it.

  3. CHECK THERMOSTAT FOR NORMAL OPERATION
    1. Remove the thermostat.
    2. Check if the thermostat is stuck or damaged.

    Is thermostat normal? 

    Yes: Go to next

    No: Replace it.

  4. CHECK ECTS RESISTANCE
    1. Measure resistance of ECTS between terminals 1 and 3 of the ECTS connector.
    Fig 1: Measuring Resistance Of ECTS Between Terminals 1 & 3 Of ECTS Connector
    G00883913Courtesy of HYUNDAI MOTOR CO.

    Is resistance within specification? 

    Yes: Proceed with ECM PROBLEM PROCEDURE  .

    No: Replace ECTS.