Code No. P0711 Oil temperature sensor system
DIAGNOSTIC TROUBLE CODE NO. P0711 - OIL TEMPERATURE SENSOR SYSTEM
| Code No. P0711 Oil temperature sensor system | Probable cause |
|---|---|
| This DTC code is set when the ATF temperature output voltage is lower than a value generated by thermistor resistance, in a normal operating range, for approximately 1 second or longer. The TCM regards the ATF temperature as fixed at a value of 80°C. |
|