FixVault

2.7 V6 Engine

  1. Remove the generator cover(A).
    Fig 1: Removing Generator Cover (V6 Engine)
    G03856984Courtesy of HYUNDAI MOTOR CO.
  2. Disconnect the slip ring guard(A).
    Fig 2: Disconnecting Slip Ring Guard (V6 Engine)
    G03856985Courtesy of HYUNDAI MOTOR CO.
  3. After loosening the 3 mounting bolts(A), detach the brush holder assembly(B).
    Fig 3: Loosening Brush Holder Assembly Mounting Bolts (V6 Engine)
    G03856986Courtesy of HYUNDAI MOTOR CO.
    CAUTION: Cutting the stator coil lead(A) line connecting to the rectifier(B) may damage the generator because the rectifier and the stator coil lead line are soldered together. So, do not disassemble further. 
    Fig 4: Detaching Brush Holder Assembly (V6 Engine)
    G03856987Courtesy of HYUNDAI MOTOR CO.
  4. Reassembly is the reverse of disassembly.