FixVault

Power Circuit Inspection

  1. IG "OFF".
  2. Disconnect the instrument cluster harness connector.
  3. Measure the voltage between terminal 11/M09-1 of harness connector and ground.

    Specification: B+

  4. Is the measured voltage within specification ?

    YES  : --> Go to "CONTROL CIRCUIT INSPECTION " procedure.

    NO  : --> Check the fuse (ECU) A 30A) between battery and cluster.

    --> Repair Open or Short in power circuit and then go to "VERIFICATION OF VEHICLE REPAIR " procedure.