FixVault

Charging System Test Procedure

  1. Press ENTER to begin charging system test.
    Fig 1: Battery Tester Screen Tool Display - Press ENTER To Begin Charging System Test
    G04801394Courtesy of HYUNDAI MOTOR CO.
  2. If ENTER button is pressed, the tester displays the actual voltage of alternator.

    Press ENTER to test the charging system.

    Fig 2: Battery Tester Screen Tool Display - Press ENTER To Test Charging System
    G04801395Courtesy of HYUNDAI MOTOR CO.
  3. Turn off all electrical load and rev engine for 5 seconds with pressing the accelerator pedal.
    Fig 3: Battery Tester Screen Tool Display - Loads Off Rev Engine 5 Sec
    G04801396Courtesy of HYUNDAI MOTOR CO.
  4. Press ENTER.
    Fig 4: Battery Tester Screen Tool Display - Loads Off Rev Engine 5 Sec
    G04801397Courtesy of HYUNDAI MOTOR CO.
  5. The MICRO 570 analyzer charging system output at idle for comparison to other readings.
    Fig 5: Battery Tester Screen Tool Display - Testing Engine At Idle
    G04801398Courtesy of HYUNDAI MOTOR CO.
  6. Take a relevant action according to the test results by referring to the table below after shutting off the engine and disconnect the tester clamps from the battery.
    Fig 6: Battery Tester Screen Tool Display - Diode Ripple Normal
    G04801399Courtesy of HYUNDAI MOTOR CO.
CHARGING SYSTEM TEST RESULTS CHART

RESULT ON PRINTER REMEDY
Charging system normal/Diode ripple normal Charging system is normal
No charging voltage Alternator does not supply charging current to battery
=> Check belts, connection between generator and battery
Replace belts or cable or generator as necessary
Low charging voltage Alternator does not supply charging current to battery and electrical load to system fully
=> Check belts and generator and replace as necessary
High charging voltage The voltage from generator to battery is higher than normal limit during voltage regulating.
=> Check connection and ground and replace regulator as necessary
=> Check electrolyte level in the battery
Excess ripple detected One or more diodes in the generator is not functioning properly
=> Check generator mounting and belts and replace as necessary