Variable Intake Solenoid (VIS) Valve: Description

Variable Intake Solenoid (VIS) Valve is installed on the intake manifold and isolates or not the one bank from the other banks to improve the intake efficiency.

  1. Low/Middle Speed: VIS Valve Close → Resonation Effect → Improving Intake Efficiency
  2. High Speed: VIS Valve Open → Improving Intake Inertia Effect → Improving Intake Efficiency
Fig 1: Identifying Variable Intake Solenoid (VIS) Valve Location
G04884279
Fig 2: Identifying Variable Intake Solenoid (VIS) Valve