DTC P0711 Transaxle Fluid Temperature Sensor Rationality: DTC Detecting Condition

DTC DETECTING CONDITION CHART

Item Detecting Condition Possible cause
DTC Strategy 
  • Check rationality
  • Sensor signal circuit is short to ground
  • Faulty sensor
  • Faulty PCM
Enable Conditions  Case 1 
  • Output Speed ≥ 1000rpm
  • Engine Speed ≥ 1000rpm
  • ATF temperature ≤ 30°C or ≤ 50°C (Ambient temp. > -7°C)
  • Accumulated time in condition ≥ 5min
Case 2 
  • Output Speed ≥ 1000rpm
  • Engine Speed ≥ 1000rpm
  • ATF temperature > 73.5°C
  • Accumulated time in condition ≥ 5min
Threshold value  Case 1 
  • Present Oil temp - Oil temp When the time starts ≤ 2°C (35.6°F)
Case 2 
  • ATF temperature ≤ -10°C
Diagnostic Time 
  • More than 1 sec
Fail Safe 
  • Learning control and Intelligent shift are inhibited