| Protective function |
Input high voltage protection |
- When input voltage is between 15V and 17V, the DC/AC inverter stops AC output.
- And when input voltage becomes less than 15V, the DC/AC inverter restart.
- When input voltage exceeds 17V furthar, the DC/AC inverter opens an own relay and shutdown itself.
|
| Input low voltage protection |
- When input voltage is less then 10.8V, the DC/AC inverter stops its AC output.
- And when input voltage exceeds 12.7V, the DC/AC inverter restart.
|
| Output high voltage protection |
- When output wave height exceeds 170V, the DC/AC inverter stops its AC output
- And when it becomes less than 170V, the DC/AC inverter restart
|
| Output over current protection |
- When the load exceeding 150W is connected to the DC/AC inverter it will be OCL (Over current limit) -mode to defend over current.
- If OCL mode continues during about 2sec, the DC/AC inverter stops its output.
- After it passes over 40sec from the DC/AC inverter stops, the inverter restarts its output.
|
| Output low voltage protection |
- When the output voltage is below the setup value, the DC/AC inverter stops its output.
- When the output low voltage protection is worked on, the DC/AC inverter shuts down.
- To restart DC/AC inverter, 'IG-off-ON' is necessary.
|
| Over heat protection |
- When the temperature inside or DC/AC inverter rises and a regular level is exceeded, the DC/AC inverter stops its output.
- When the over heat protection is worked on, the DC/AC inverter shuts down.
- To restart DC/AC inverter, 'IG-off-ON' is necessary
|
| Outlet LED |
- When the DC/AC inverter is providing AC power, outlet LED is lighting.
- When input voltage is between 11.0 and 10.8, outlet LED is blinking (The blink frequency is about 2Hz.)
- When input voltage is under 10.8V, outlet LED is stops operating.
- When the DC/AC inverter is not providing AC power, outlet LED is unlighting.
|