Component Inspection

  1. Inspect the CVVT system.
  2. Measure the resistance of OCV.

    RESISTANCE 

    OCV RESISTANCE SPECIFICATIONS

    Temperature °C (°F) Resistance (Ω)
    0 (32) 6.2 ~ 7.4
    20 (68) 6.8 ~ 8.0
    40 (104) 7.4 ~ 8.6
    60 (140) 8.0 ~ 9.2
    80 (176) 8.6 ~ 9.8
    Fig 1: Measuring Resistance Of OCV
    G04890882Courtesy of HYUNDAI MOTOR CO.
  3. Measure the resistance of OTS.

    RESISTANCE 

    OTS RESISTANCE SPECIFICATIONS

    Temperature °C (°F) Resistance (kΩ)
    -40 (-40) 52.15
    -30 (-22) 28.82
    -10 (-14) 9.80
    0 (32) 6
    20 (68) 2.45
    40 (104) 1.10
    50 (122) 0.77
    60 (140) 0.54
    70 (158) 0.39
    90 (194) 0.22
    100 (212) 0.16
    110 (230) 0.13
    120 (248) 0.10
    130 (266) 0.08
    Fig 2: Measuring Resistance Of OTS
    G04890883Courtesy of HYUNDAI MOTOR CO.