FixVault

Starter Solenoid Test: Notes

  1. Check the hold-in coil for continuity between the S terminal and the armature housing (ground). The coil is OK if there is continuity.
    Fig 1: Checking Hold-In Coil For Continuity Between S Terminal And Armature Housing (Ground)
    G03849061Courtesy of HYUNDAI MOTOR CO.
  2. Check the pull-in coil for continuity between the S and M terminals. The coil is OK if there is continuity.